Phares Electronics Digital Output Hall Effect Sensors

Phares Electronics Digital Output Hall Effect Sensors

Phares Electronics Digital Output Hall Effect Sensors

Phares Electronics Digital Output Hall Effect Sensors are some of the most robust and reliable on the market today.  They are designed for, shall we say, “less than desirable” environments, such as high temperature, wash down areas, outdoor, oil, dust, dirt, corrosive, heavy vibration and more.  Of course, they work in clean environments as well!  Some of the Phares Digital Output Hall Effect Sensors have 1/2″ NPT threads which conveniently seal to 1/2″ conduit.

Phares Electronics Digital Output Hall Effect SensorsDownload or view as PDF:

 

Phares Hall Effect Sensors are simple on/off non-contact switching (NPN) devices.  They are magnetically activated sensors that detect the motion or position of a magnetic target.  Omnipolar operation activates sensor with either a north or south polarity field.

The digital output is a square-wave frequency signal that is directly proportional to the input (linear). The digital output signal is compatible with logic inputs (PLC, VFD, DCS) and other devices that can measure frequency directly. This includes Phares Industrial Tachometers and Motion Detector Modules.

 

Phares Electronics Digital Output Hall Effect Sensors have an NPN (sinking) output; PNP (sourcing) output is available.

 

“Tiny Tim” Ultra Mini Hall Effect Sensors

Phares Electronics Digital Output Ultra Mini Hall Effect Sensor and Dimensions

Part Number

Barrel Length

Cable Length

Operating Temperature

UMS03-013"1'-40° F to 140° F
UMS03-063"6'-40° F to 140° F
UMS03-103"10'-40° F to 140° F
3"1'-40° F to 300° F
3"6'-40° F to 300° F
3"10'-40° F to 300° F
Custom cable lengths available!

 

Phares Electronics Mini Hall Effect Sensors

Phares Electronics Mini Hall Effect Sensor and Dimensions

Part Number

Barrel Length

Cable Length

Operating Temperature

MGS0403-013"1'-40° F to 140° F
MGS0403-063"6'-40° F to 140° F
MGS0403-103"10'-40° F to 140° F
MGHTS0403-013"1'-40° F to 300° F
MGHTS0403-063"6'-40° F to 300° F
MGHTS0403-103"10'-40° F to 300° F
Custom cable lengths available!

 

Phares Electronics Hall Effect Sensors with 1″ Long Barrel

Phares Electronics Digital Output Hall Effect Sensor 1'' Long Barrel

Part NumberBarrel LengthCable LengthOperating Temperature
S0401-011"1'-40° F to 140° F
S0401-061"6'-40° F to 140° F
S0401-101"10'-40° F to 140° F
HTS0401-011"1'-40° F to 300° F
HTS0401-061"6'-40° F to 300° F
HTS0401-101"10'-40° F to 300° F
Custom cable lengths available!

 

Phares Electronics Hall Effect Sensors with 1.5″ Long Barrel

Phares Electronics Digital Output Hall Effect Sensor 1.5'' Long-Barrel

Part NumberBarrel LengthCable LengthOperating Temperature
S0415-011.5"1'-40° F to 140° F
S0415-061.5"6'-40° F to 140° F
S0415-101.5"10'-40° F to 140° F
HTS0415-011.5"1'-40° F to 300° F
HTS0415-061.5"6'-40° F to 300° F
HTS0415-101.5"10'-40° F to 300° F
Custom cable lengths available!

 

Phares Electronics Hall Effect Sensors with 2″ Long Barrel

Phares Electronics Digital Output Hall Effect Sensor 2'' Long Barrel

Part NumberBarrel LengthCable LengthOperating Temperature
S0402-012"1'-40° F to 140° F
S0402-062"6'-40° F to 140° F
S0402-102"10'-40° F to 140° F
HTS0402-012"1'-40° F to 300° F
HTS0402-062"6'-40° F to 300° F
HTS0402-102"10'-40° F to 300° F
Custom cable lengths available!

 

Phares Electronics Hall Effect Sensors with 3″ Long Barrel

Phares Electronics Digital Output Hall Effect Sensor 3'' Long Barrel

Part NumberBarrel LengthCable LengthOperating Temperature
S0403-013"1'-40° F to 140° F
S0403-063"6'-40° F to 140° F
S0403-103"10'-40° F to 140° F
HTS0403-013"1'-40° F to 300° F
HTS0403-063"6'-40° F to 300° F
HTS0403-103"10'-40° F to 300° F
Custom cable lengths available!

 

Phares Electronics Hall Effect Sensors with 4″ Long Barrel

Phares Electronics Digital Output Hall Effect Sensor 4'' Long Barrel

Part NumberBarrel LengthCable LengthOperating Temperature
S0404-014"1'-40° F to 140° F
S0404-064"6'-40° F to 140° F
S0404-104"10'-40° F to 140° F
HTS0404-014"1'-40° F to 300° F
HTS0404-064"6'-40° F to 300° F
HTS0404-104"10'-40° F to 300° F
Custom cable lengths available!

 

Installation

Most of the Phares Hall Effect Sensors can be secured via ½” conduit fitting, bracket, or both. Various sensor housing lengths allow greater flexibility regarding mounting and bracket location. Use a Phares Terminal Strip Assembly (TSA) Box for quick mounting and termination, and applications which require long cable runs.

Phares Electronics Digital Output Hall Effect Sensor Wiring DiagramPhares Electronics Digital Output Hall Effect Sensor Wiring Diagram